ENTER/EXIT PROGRAMMING MODE

Expand Code128 to Code 39

Enables/disables expansion of Code 128 labels to Code 39.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan either the enable or disable barcode below. You'll need to cover any unused bar‐
codes on this and the facing page to ensure that the scanner reads only the barcode
you intend to scan.
3. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode barcode.
DEFAULT
069601(CR)
Expand Code128 to Code 39 = Enable
212
MAGELLAN™ 1500I
069600(CR)
Expand Code128 to Code 39 = Disable