ENTER/EXIT PROGRAMMING MODE

Sleep Mode Timer

This feature specifies the amount of time of inactivity (with no label reads) before the scan‐
ner enters sleep mode.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode
codes on this and the facing page to ensure that the scanner reads only the barcode
you intend to scan.
3. Scan the appropriate digits from the
the desired time interval. The selectable range is 000‐255 in 15 second increments.
Pad all numbers with leading zeros to yield a three‐digit entry (000‐255).
4. Scan the Enter/Exit Programming Mode barcode at the top of the page to exit Pro‐
gramming Mode.
DEFAULT
36
MAGELLAN™ 1500I
below. You'll need to cover any unused bar‐
Set Sleep Mode Timer
Alpha-Numeric Keypad in Appendix C
03AF(CR)
Default setting for this feature is: 5 minutes
Set Sleep Mode Timer
to represent