Chapter 4

AdeptWindows PC Graphical User Interface

When using AdeptWindows as the graphical user interface, DIP switch SW1 must
be set to one of the following:
Table 4-4. AdeptWindows Interface DIP Switch SW1 Settings
SW 4
SW 3 SW 2
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
  
used to connect the AWC module to an Ethernet network. Use only
hubs that provide shielded RJ45 connectors. Adept cannot ensure
safe and reliable operation of the Ethernet connection without
proper shielding of all the Ethernet connectors and cables.

When connecting to a hub, use a straight-through cable that
connects the "Transmit" and the "Receive" pairs to the same pins on
both ends of the cable. When connecting to a server/PC directly, use
a cross-over cable that swaps the placement of the transmit and
receive pairs on the opposite ends.

VGB Graphical User Interface

When using the VGB graphical user interface, DIP switch SW1 must be set as
follows:
Table 4-5. VGB User Interface Settings of DIP Switch SW1
SW 4
SW 3 SW 2
ON
ON
ON
80
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
SW 1
Interpretation
OFF
CPU #1, no auto boot, user interface via serial
AdeptWindows
ON
CPU #1, no auto boot, user interface via Ethernet
AdeptWindows (use IP address in
OFF
CPU #1, no auto boot, user interface via Ethernet
AdeptWindows (use default IP address)
Adept strongly recommends shielded Ethernet cables be
SW 1
Interpretation
OFF
CPU #1, no auto boot, user interface via VGB or serial
port (use serial port if VGB is absent, or if a VGB is
present but its use is disabled with its DIP switch #4)
Adept MV Controller User's Guide, Rev. B
Configuring an AWC Module