Connecting Ac Power Cord; System Grounding Information; Fuse Information (Mv-5 And Mv-10) - adept technology MV User Manual

Hide thumbs Also See for MV:
Table of Contents

Advertisement

Chapter 3

Connecting AC Power Cord

The AC power cord is included in the accessory kit. The controller end of the
power cord is fitted with an IEC 320 connector. The user end of the cord is not
terminated. Connect each conductor of the power cord securely to your AC
power source, using the color code below. You must provide a suitable plug or
other facility connection in accordance with all applicable local and national
codes. See the next section for important information on system grounding.
Cord length
Cord rating
Number and size of
conductors
Color code

System Grounding Information

The detachable three-wire power cord is used for connection to both the power
source and protective ground. The protective ground conductor (colored
green/yellow) in the power cord is internally connected to the exposed metal
parts of the MV Controller. To ensure electrical-shock protection, the protective
ground conductor must be connected to a properly grounded power source.
  
before turning on the power.

Fuse Information (MV-5 and MV-10)

The two fuses (F1 and F2) at the power entry module on the front panel are for the
incoming AC power lines. See the table below for ratings.
  
change any fuses. Always replace blown fuses with new fuses of the
same type and rating.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 3-3. Power Cord Specifications
3 meters ±0.1 m (9 ft. 10 in. ±4 in.)
10 amps
3 x 1.00 mm
line
brown
neutral
blue
ground
green/yellow
Ensure that a proper protective ground connection exists
Only skilled or instructed personnel should attempt to
Adept MV Controller User's Guide, Rev. B
Installing the MV-5 and MV-10 Controllers
2
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mv-5Mv-10Mv-4

Table of Contents