Two pairs of pins on the JUSER connector (pins 6, 25 and 7, 26) provide
connection for an MCP enable switch (momentary push button). This input
duplicates the functionality of the MCP enable switch on MCP. Electrically, the
enable switch is wired in series with the MCP enable switch connections on the
CIP. If the MCP is connected remotely using the remote MCP connection on the
JUSER connector, wire the MCP enable switch of the MCP to these pins.

These pins must be shorted if not used.

The MCP III uses only one switch channel for the Enable
function. (The MCP ESop button uses two channels.) The MCP
Enable switches E-stop channel 1 directly while channel 2 is
switched by a sense relay (DM1 in '  ( ).
This means that only channel 1 of the Remote Enable Switch is
active! Please contact Adept for custom modifications of the MCP III
or MCP bypass plug if you need a two-channel MCP enable
function.