Chapter 3
International (partial list): Germany (0894)-600990, France (1) 39-44-00-44,
UK (01734)-342200, Taiwan (238)-81305, Singapore 553-4900.
All others, call USA (408) 473-1800.
(Phone numbers correct as of November 1997. Source: Wyse USA)

Customer-Supplied Serial Interface Cable

A Wyse WY-60 terminal has a 25-pin female D subminiature connector (DB-25F),
which requires a 25-pin male connector (DB-25M) on the interface cable. The
AWC board RS-232/Term connector is a 9-pin male connector (DE-9P) which
requires a 9-pin female connector (DE-9F). See
details on connecting a Wyse terminal to an AWC board.
If you are using a terminal other than a Wyse WY-60, check the documentation on
the serial connector before you purchase or build the serial interface cable.

Installation Procedure

1. Make sure the controller is turned off before making any connections.
2. Verify that the voltage range marked on the terminal is compatible with your
local voltage source. Connect the AC power cord to the terminal, then plug it
into an appropriate voltage source.
3. Connect a suitable serial cable between the terminal and the RS-232/Term
connector on the system processor board.
4. If the terminal is a Wyse 60, use the setup mode to set the personality to
"WY-75". If you are using terminal emulation software on a computer, set the
software to "WY-75" emulation. If "WY-75" is not available, try "VT102" or
"VT100", however, you will not be able to use all of the function keys.
5. Set the baud rate to 9600, the default rate for the Adept system. To change the
Adept system baud rate, refer to the information on
      .

Installing a Stand-Alone Controller in a Rack or Panel

An MV-5 or MV-10 stand-alone controller can be mounted in a standard 19-inch
equipment rack using the attached mounting brackets. The brackets also can be
moved to the rear of the controller for panel mounting.
There is no stand-alone version of the Compact Controller.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Installing a Stand-Alone Controller in a Rack or Panel

Adept MV Controller User's Guide, Rev. B
"ASCII Terminal" on page 81
in the manual
*/7)8
for
67