Procedure To Remove Fuse Holder; Adept Mv Controller User's Guide, Rev. B; Fan And Filter Information (Mv-5 And Mv-10); Cooling Fan - adept technology MV User Manual

Hide thumbs Also See for MV:
Table of Contents

Advertisement

Chapter 3

Procedure to Remove Fuse Holder

1.
Turn off AC power to the controller and disconnect the power cord from the
AC power source.
2.
Remove the AC power cord from the socket on the power entry module.
3.
To remove the fuse holder, insert a small flat-blade screwdriver into the slot
between the fuse holder and the power cord socket, then lift up to release the
fuse holder; see
4. To reinstall the fuse holder, insert it in place, then press down firmly until the
entire holder snaps into position.
Fuse
F1 – AC Line fuse at Power
Entry module
F2 – AC Line fuse at Power
Entry module

The "T" suffix indicates the fuse response time — a 5 AT fuse
rating specifies a 5 amp "slow-blow" type.
Fuse Holder
Fuse Holder

Fan and Filter Information (MV-5 and MV-10)

Cooling Fan

The chassis is cooled by an internal fan. On a robot controller, the air intake is
through the bottom of the chassis, and the exhaust is out through the top. On a
stand-alone controller, the air intake is through the right side of the chassis, and
the exhaust is out through the left side.
56
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Figure
3-2. Spare fuses are stored in the sliding compartments.
Table 3-4. MV-5 and MV-10 Fuse Ratings
Rating
5 AT/250 V
5 AT/250 V
Figure 3-2. MV-5/MV-10 Fuse Holder

Adept MV Controller User's Guide, Rev. B

Installing the MV-5 and MV-10 Controllers
Type
IEC 127-style
5 x 20 mm
IEC 127-style
5 x 20 mm
Spare fuses
Spare fuses
in sliding
in sliding
compartment
Fuses
compartment
Fuses
F1 and
F1 and F2
F2
Side view of
Side view of
fuse holder
Fuse Holder