Optional Dio Cables; Labeling Cables; Input And Output Cable Wiring Information - adept technology MV User Manual

Hide thumbs Also See for MV:
Table of Contents

Advertisement

Chapter 12

Optional DIO Cables

Cables to connect the input and output connectors on the DIO board to the DIO
devices can be ordered as a set of four cables: two input cables and two output
cables. These cables have a mating plug on one end and unterminated flying
leads on the other end. The wire size of the Adept cables is 0.18 mm
You can use these cables to connect to the digital inputs/outputs in your system
or to a wiring block.
To comply with IEC 1131, if you choose to supply a wiring block, it should be
capable of accepting wire in the range of 0.18 mm
AWG).

Labeling Cables

The P1 and P2 input connectors on the front of the board are similar except that P1
handles the Group 1 and 2 input signals and P2 handles the Group 3 and 4 input
signals. The optional digital input cables can be connected to either P1 or P2.
Make sure to clearly label the cables once you have completed your installation so
that the cables do not get swapped by mistake; see the Warning below.
The P3 and P4 output connectors are also similar except that P3 handles the
Group 1 and 2 output signals and P4 handles the Group 3 and 4 output signals.
The optional digital output cables can be connected to either P3 or P4. Make sure
to clearly label the cables once you have completed your installation so that the
cables do not get swapped by mistake; see the Warning below.
  
so that they are always plugged into the correct connector.
Swapping the P1 and P2 or P3 and P4 cables could cause damage to
your equipment. Depending on the installation, this could
potentially cause injury to personnel in the area. Also, if you have
more than one DIO board, make sure each set of cables is clearly
labeled so they don't get plugged into the wrong board by mistake.

Input and Output Cable Wiring Information

The pinouts, signal names, and wire color information for the input and output
cables are shown in
200
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Make sure to clearly label the P1 to P4 digital I/O cables
Table 12-4
through
Adept MV Controller, User's Guide, Rev. B
2
(24 AWG) to 2.0 mm
Table
12-7.

Optional DIO Cables

2
(24AWG).
2
(14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mv-5Mv-10Mv-4