Row #
SW 1
SW 2
1
ON
ON
2
OFF
ON
3
ON
ON
4
OFF
ON
5
OFF
OFF
NOTE: SW1 is configured by Adept to a default configuration listed in
row #5 of
NVRAM settings. Adept recommends that the user maintain this default
SW1 configuration for normal SmartController operation. The default
NVRAM settings are auto boot, ethernet, and use default IP address. The use
of any settings other than those in
results.
NOTE: The default IP address for the controller is located on a label on the
bottom side of the controller chassis.

AdeptWindows PC Graphical User Interface

When using the AdeptWindows graphical user interface, DIP switch SW1 cannot be set to
the switch settings shown in row #2 of
NOTE: Adept recommends using switches instead of hubs when making
Ethernet connections to the controller. When connecting to a switch, use a
straight-through cable that connects the "Transmit" and the "Receive"
pairs to the same pins on both ends of the cable. When connecting to a
server/PC directly, use a cross-over cable that swaps the placement of the
transmit and receive pairs on the opposite ends.

ASCII Terminal

When using an ASCII Terminal or terminal-emulation software as the user interface, DIP
switch SW1 must be set to the switch settings shown in row #2 of

Table 3-3. SW1 Settings

SW 3
SW 4
ON
ON
No auto boot, all other settings per CompactFlash
ON
ON
No auto boot, user interface via serial port
No auto boot, user interface via Ethernet
OFF
ON
AdeptWindows (use IP address in CompactFlash)
No auto boot, user interface via Ethernet
OFF
ON
AdeptWindows (use default IP address)
OFF
OFF
Operation per CompactFlash and NVRAM settings
Table 3-3
(OFF-OFF-OFF-OFF) to use the CompactFlash and
Table
CAUTION:
Adept strongly recommends using shielded
Ethernet cables to connect the SmartController to an
Ethernet network. Use only switches (not hubs) that
provide shielded RJ-45 connectors. Adept cannot ensure
reliable operation of the Ethernet connection without
proper shielding of all the Ethernet connectors and cables.
Adept SmartController User's Guide, Rev. E
Configuring the Controller
Interpretation
Table 3-3
will cause unpredictable
3-3.
Table
3-3.
43