Parts Replacement and Cleaning > Fixing System > Cleaning the Fixing Separation Guide > Procedure
CAUTION:
Point to Note when Installing the Fixing Separation Guide:
Be sure to check that Fixing Separation Guide [1] is installed properly.
[1]
SIDE VIEW
[A]
Example of improper installation:
• Illustration at the center: The Fixing Separation Guide is placed on the rib [A].
• Illustration at the right: The Fixing Separation Guide is installed in opposite direction.
Checking method:
• After installing the Fixing Separation Guide, swing the guide with your finger. If it is
installed properly, it is stable. If not, it becomes wobbly.
• When installing the Leaf Spring while the guide is not installed properly, the spring
will be expanded awkwardly.
4
Parts Replacement and Cleaning > Fixing System > Cleaning the Fixing Separation Guide > Procedure
Cleaning the Fixing Separation Guide
■ Preparations
1) Open the Right Lower Cover and Right Upper Cover.
2) Remove the Fixing Unit.
3) Remove the Film Unit.
■ Procedure
1) Clean the Fixing Separation Guide with lint-free paper moistened with alcohol.
F-4-279