COPIER > ADJUST > HV-PRI
OFSTAC-M
Adj M charge AC voltage (1/1 speed)
Lv.1 Details
To adjust the offset of the charge AC voltage for M.
As the value is incremented by 1, the voltage value is increased by
20 Vpp.
Decrease the value when image smear occurs, and increase the
value when image failure (sand-like image) occurs.
Use case
• When image smear occurs
• When an image failure (sand-like image) occurs
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Caution
• Do not use this when the machine is operating correctly.
• Use OFSTAC-M only when image failure is not alleviated by
making adjustment with DIS-TGM. In this case, be sure to return
DIS-TGM to its original setting.
• If the value is too large, the life of the Photosensitive Drum
becomes shorter.
Display/adj/set range
-20 to 20
Unit
V
Default value
0
Related service mode
COPIER> ADJUST> HV-PRI> DIS-TGM
OFSTAC-C
Adj C charge AC voltage (1/1 speed)
Lv.1 Details
To adjust the offset of the charge AC voltage for C.
As the value is incremented by 1, the voltage value is increased by
20 Vpp.
Decrease the value when image smear occurs, and increase the
value when image failure (sand-like image) occurs.
Use case
• When image smear occurs
• When an image failure (sand-like image) occurs
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Caution
• Do not use this when the machine is operating correctly.
• Use OFSTAC-C only when image failure is not alleviated by
making adjustment with DIS-TGC. In this case, be sure to return
DIS-TGC to its original setting.
• If the value is too large, the life of the Photosensitive Drum
becomes shorter.
Display/adj/set range
-20 to 20
Unit
V
Default value
0
Related service mode
COPIER> ADJUST> HV-PRI> DIS-TGC
8
Service Mode > COPIER > ADJUST > HV-PRI
8
Service Mode > COPIER > ADJUST > HV-PRI
COPIER > ADJUST > HV-PRI
OFSTAC-K
Adj Bk charge AC voltage (1/1 speed)
Lv.1 Details
To adjust the offset of the charge AC voltage for Bk.
As the value is incremented by 1, the voltage value is increased by
20 Vpp.
Decrease the value when image smear occurs, and increase the
value when image failure (sand-like image) occurs.
Use case
• When image smear occurs
• When an image failure (sand-like image) occurs
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Caution
• Do not use this when the machine is operating correctly.
• Use OFSTAC-K only when image failure is not alleviated by
making adjustment with DIS-TGK. In this case, be sure to return
DIS-TGK to its original setting.
• If the value is too large, the life of the Photosensitive Drum
becomes shorter.
Display/adj/set range
-20 to 20
Unit
V
Default value
0
Related service mode
COPIER> ADJUST> HV-PRI> DIS-TGK
OFSTACY2
Adj Y charge AC voltage (1/2 speed)
Lv.1 Details
To adjust the offset of the charge AC voltage for Y at 1/2 speed.
As the value is incremented by 1, the voltage value is increased by
20 Vpp.
Decrease the value when image smear occurs, and increase the
value when image failure (sand-like image) occurs.
Use case
• When image smear occurs
• When an image failure (sand-like image) occurs
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Caution
• Do not use this when the machine is operating correctly.
• Use OFSTACY2 only when image failure is not alleviated by
making adjustment with DIS-TGY2. In this case, be sure to return
DIS-TGY2 to its original setting.
Display/adj/set range
-20 to 20
Unit
V
Default value
0
Related service mode
COPIER> ADJUST> HV-PRI> DIS-TGY2
8-113
8-113

Advertisement

loading