7) Remove the Fan Duct 1.
• 2 screws
• 1 connector
• 1 claw
Claw
x2
8) Remove the harness of Hopper.
• 8 connectors
x8
4
Parts Replacement and Cleaning > Image Formation System > Removing the Main Drive Unit > Procedure
Connector
Fan duct
F-4-227
Connectors
Connectors
F-4-228
9) Remove the 9 connectors and 10 Wire Saddles from the Drum Driver PCB.
Wire saddles
x9
x10
Wire saddles
Connectors
10) Remove the Main Drive Unit.
• 2 connectors
• 6 screws
x2
x6
Main drive unit
4-130
Wire saddles
Connectors
Wire saddles
Connectors
Wire saddle
Drum driver PCB
Connectors
F-4-229
Connectors
F-4-230