PSWD-SW
Password type set to enter service mode
Lv.1 Details
To set the type of password that is required to enter when getting into
service mode.
2 types are available: one for "service technician" and the other for
"system administrator + service technician".
When selecting the type for "system administrator + service
technician", enter the password for service technician after the
password entry by the user's system administrator.
Use case
Upon request from the user who concerns security
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2
0: No password, 1: Service technician, 2: System administrator +
service technician
Default value
0
SM-PSWD
Password setting for service technician
Lv.2 Details
To set password for service technician that is used when getting into
service mode.
Use case
When password is required to get into service mode
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to select 1 or 2 for PSWD-SW in advance.
Display/adj/set range
1 to 99999999
Default value
11111111
Related service mode
COPIER> OPTION> FNC-SW> PSWD-SW
RPT2SIDE
Set of report 1-sided/2-sided output
Lv.1 Details
To set whether to use 1-sided or 2-sided for report output of service
mode.
Use case
When making 2-sided report output to reduce the number of output
pages
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: 1-sided, 1: 2-sided
Default value
1
Related service mode
COPIER> FUNCTION> MISC-P> P-PRINT
8
Service Mode > COPIER > OPTION > FNC-SW
8
Service Mode > COPIER > OPTION > FNC-SW
COPIER > OPTION > FNC-SW
PSCL-MS
Set of auto gradation adjustment: Heavy
Lv.1 Details
To set at which speed (1/1 speed, 1/2 speed, or 1/3 speed) PASCAL
control and D-half control are executed at auto gradation adjustment.
When 2 is set, it is executed only for the lastly used speed only. The
time required for auto gradation adjustment is short, but switching
to another speed takes time. This is suitable for the users who
frequently use a specific paper type.
When 3 is set, it is executed for all speeds. The time required for
auto gradation adjustment is long (approx. 3 minutes), but switching
to another speed is quick. This is suitable for the users who use
various paper types.
Use case
When setting the speed according to the materials used by the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
2 to 3
2: Lastly used speed, 3: All speed
Default value
2
DMX-DISP
ON/OFF auto grdtn adj D-max PASCAL ctrl
Lv.1 Details
To set whether to execute D-max PASCAL control at full adjustment
of auto gradation adjustment.
When 0 is set, D-max PASCAL control and PASCAL control are
executed. Four A4-size sheets are used for test prints (one for D-max
PASCAL control and three for PASCAL control).
When 1 is set, PASCAL control (gradation adjustment) only is
executed. Three A4-size sheets are used for test prints (for PASCAL
control).
Use case
When making the setting according to the usage of the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: ON, 1: OFF
Default value
0
STND-PNL
Not used
INVALPDL
Disabling PDL license
Lv.1 Details
To disable the registered PDL license.
When "1: Disabled" is set, PDL is disabled even if a PDL license
is registered. This is set to the machines installed at convenience
stores, which do not allow PDL to be used.
Use case
When prohibiting the use of PDL
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Registered PDL license is enabled, 1: Disabled
Default value
0