COPIER > OPTION > IMG-FIX
PLN-LP
Set of fixing arch ctrl with plain paper
Lv.2 Details
To set the arch control method between the secondary transfer and
fixing when feeding plain paper, color paper or recycled paper (52 to
105 g/m2).
Normally, the arch control is executed at the point where arch on the
trailing edge of paper is small.
When 1 is set in the case that an image failure (crepe mark) occurs
with plain paper, color paper or recycled paper, the control is always
executed at the point where the arch on a paper is large while
feeding plain paper, color paper or recycled paper.
Use case
When an image failure (crepe mark) occurs with plain paper, color
paper or recycled paper
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Arch control at the point where arch is small, 1: Arch control to
make the arch large with plain paper, color paper or recycled paper
Default value
0
TRC-LP
Set fixing arch ctrl with tracing paper
Lv.2 Details
To set the arch control method between the secondary transfer and
fixing when feeding tracing paper.
Normally, the arch control is executed at the point where arch on the
trailing edge of paper is small.
When 1 is set in the case that an image failure (crepe mark) occurs
with tracing paper, the control is always executed at the point where
the arch on a paper is large while feeding tracing paper.l
Use case
When an image failure (crepe mark) occurs with tracing paper
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Arch control at the point where arch is small, 1: Arch control to
make the arch large with tracing paper
Default value
0
8
Service Mode > COPIER > OPTION > CUSTOM
T-8-59
8
Service Mode > COPIER > OPTION > CUSTOM
■ CUSTOM
COPIER > OPTION > CUSTOM
TEMP-TBL
Fixing control temperature:Plain paper 1
Lv.1 Details
To set the offset of fixing control temperature for plain paper 1 (64 to
81 g/m2).
As the value is incremented by 1, the control temperature is
increased by 5 deg C.
Increase the value when a fixing failure occurs.
Decrease the value when fixing offset occurs.
Use case
When offset/fixing failure occurs on plain paper 1
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default value
0
SC-L-CNT
Set large paper jdgmt reference at scan
Lv.1 Details
To set the judgment reference of the scan counter as to which to use
B4 or LTR to determine large size.
The threshold is determined by the combination with the setting of
B4-L-CNT.
SC-L-CNT=0, B4-L-CNT=0: paper exceeding B4 is determined as
large size, paper with B4 or smaller is determined as small size.
SC-L-CNT=0, B4-L-CNT=1: paper with B4 or larger is determined as
large size, paper smaller than B4 is determined as small size.
Use case
As needed
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: B4 size, 1: LTR size
Default value
0
Related service mode
COPIER> OPTION> USER> B4-L-CNT
SCANTYPE
Switch of DADF + Reader
Lv.1 Details
To switch to a different type DADF + Reader Unit.
Use case
At installation
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Reverse Duplex DADF + Reader, 1: 1-Path Duplex DADF +
Reader
Default value
0
8-204