Download Print this page

Canon imageRUNNER ADVANCE C5051 Series Service Manual page 731

Hide thumbs Also See for imageRUNNER ADVANCE C5051 Series:

Advertisement

■ CST-STS
COPIER(1)>DISPLAY(1)>CST-STS(5)(list:1)
WIDTH-MF
Dspl Multi-purpose Tray paper width size
Lv.2 Details
To display the paper width size set on the Multi-purpose Tray.
Use case
When checking the paper width side set on the Multi-purpose Tray
Display/adj/set range
Numeric value
Unit
mm
8
Service Mode > COPIER > DISPLAY > HV-STS
T-8-6
8
Service Mode > COPIER > DISPLAY > HV-STS
■ HV-STS
COPIER > DISPLAY > HV-STS
1ATVC-Y
Dspl of primary transfer current (Y)
Lv.2 Details
To display the decuple value of the current flown to the Primary
Transfer Roller (Y) by the primary transfer ATVC control.
When the two values are out of the target value range (50 to 700),
clear the log information for the appropriate control (COPIER>
FUNCTION> CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may
have reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Display/adj/set range
0 to 900
Unit
uA
Appropriate target value 50 to 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
1ATVC-M
Dspl of primary transfer current (M)
Lv.2 Details
To display the decuple value of the current flown to the Primary
Transfer Roller (M) by the primary transfer ATVC control.
When the two values are out of the target value range (50 to 700),
clear the log information for the appropriate control (COPIER>
FUNCTION> CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may
have reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Display/adj/set range
0 to 900
Unit
uA
Appropriate target value 50 to 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
1ATVC-C
Dspl of primary transfer current (C)
Lv.2 Details
To display the decuple value of the current flown to the Primary
Transfer Roller (C) by the primary transfer ATVC control.
When the two values are out of the target value range (50 to 700),
clear the log information for the appropriate control (COPIER>
FUNCTION> CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may
have reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Display/adj/set range
0 to 900
Unit
uA
Appropriate target value 50 to 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
8-31
8-31

Advertisement

loading