COPIER > DISPLAY > HT-C
TGT-C-C
Dspl ARCDAT screen C C-color target VL
Lv.2 Details
To display the C-patch target value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-C-K
Dspl of ARCDAT screen C Bk-clr target VL
Lv.2 Details
To display the Bk-patch target value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor if not alleviated.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
SUM-A-Y
Dspl ARCDAT screen A Y-color ctrl differ
Lv.2 Details
To display Y-patch control difference of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-A-M
Dspl ARCDAT screen A M-color ctrl differ
Lv.2 Details
To display M-patch control difference of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-A-C
Dspl ARCDAT screen A C-color ctrl differ
Lv.2 Details
To display C-patch control difference of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
8
Service Mode > COPIER > DISPLAY > HT-C
8
Service Mode > COPIER > DISPLAY > HT-C
COPIER > DISPLAY > HT-C
SUM-A-K
Dspl ARCDAT screen A Bk-clr ctrl differ
Lv.2 Details
To display Bk-patch control difference of screen A in ARCDAT
control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-B-Y
Dspl ARCDAT screen B Y-color ctrl differ
Lv.2 Details
To display Y-patch control difference of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-B-M
Dspl ARCDAT screen B M-color ctrl differ
Lv.2 Details
To display M-patch control difference of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-B-C
Dspl ARCDAT screen B C-color ctrl differ
Lv.2 Details
To display C-patch control difference of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-B-K
Dspl ARCDAT screen B Bk-clr ctrl differ
Lv.2 Details
To display Bk-patch control difference of screen B in ARCDAT
control.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
8-45