COPIER > FUNCTION > SYSTEM
DEBUG-1
Setting of log type and save timing
Lv.2 Details
To set the types of logs to be stored and the timing to store logs in
the HDD.
Logs are used to analyze the cause of a problem.
Use case
When analyzing the cause of a problem
Adj/set/operate method Select the item, and then press OK key.
Caution
Do not use this at the normal service. Change the setting value in
accordance with the instructions from the Quality Support Division.
Display/adj/set range
0 to 3
0: Save PLOG at detection of Reboot/Exception
1: Save PLOG at detection of Reboot/Exception/Encode
2: Save SUBLOG at detection of Reboot/Exception/Encode
3: Save SUBLOG in overwrite mode at detection of Reboot/
Exception/Encode
Default value
3
Related service mode
COPIER> FUNCTION> SYSTEM> DEBUG-2(LEVEL2)
DEBUG-2
Output of log saved on HDD
Lv.2 Details
To print the PLOG saved in HDD by COPIER> FUNCTION>
SYSTEM> DEBUG-1. (A4: Approx. 20 sheets)
SUBLOG is not printed. It should be uploaded from SST or USB.
Use case
When printing PLOG
Adj/set/operate method Select the item, and then press OK key.
Caution
Do not use this at the normal service.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode
COPIER> FUNCTION> SYSTEM> DEBUG-1(LEVEL2)
CDS-UPDT
[Not used]
DSRAMBUP
Backup of DC Controller PCB SRAM
Lv.2 Details
To back up the setting data in SRAM of the DC Controller PCB.
Use case
When replacing the DC Controller PCB for troubleshooting at the
time of problem occurrence
Adj/set/operate method Select the item, and then press OK key.
Caution
During operation, the setting data changes by manual or automatic
adjustment. When backup data which has been left for a long period
of time is restored, it is overwritten with new setting data and the old
data is deleted.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode
COPIER> FUNCTION> SYSTEM> DSRAMRES
8
Service Mode > COPIER > FUNCTION > SYSTEM
8
Service Mode > COPIER > FUNCTION > SYSTEM
COPIER > FUNCTION > SYSTEM
DSRAMRES
Restore of DC Controller PCB SRAM
Lv.2 Details
To restore the setting data which has been backed up in SRAM of
the DC Controller PCB.
Use case
When replacing the DC Controller PCB for troubleshooting at the
time of problem occurrence
Adj/set/operate method Select the item, and then press OK key.
Caution
During operation, the setting data changes by manual or automatic
adjustment. When backup data which has been left for a long period
of time is restored, it is overwritten with new setting data and the old
data is deleted.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode
COPIER> FUNCTION> SYSTEM> DSRAMBUP
RSRAMBUP
Backup of Reader Controller PCB SRAM
Lv.2 Details
To back up the setting data in SRAM of the Reader Controller PCB.
Use case
When replacing the Reader Controller PCB for troubleshooting at the
time of problem occurrence
Adj/set/operate method Select the item, and then press OK key.
Caution
During operation, the setting data changes by manual or automatic
adjustment. When backup data which has been left for a long period
of time is restored, it is overwritten with new setting data and the old
data is deleted.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode
COPIER> FUNCTION> SYSTEM> RSRAMRES
RSRAMRES
Restore of Reader Controller PCB SRAM
Lv.2 Details
To restore the setting data which has been backed up in SRAM of
the Reader Controller PCB.
Use case
When replacing the Reader Controller PCB for troubleshooting at the
time of problem occurrence
Adj/set/operate method Select the item, and then press OK key.
Caution
During operation, the setting data changes by manual or automatic
adjustment. When backup data which has been left for a long period
of time is restored, it is overwritten with new setting data and the old
data is deleted.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode
COPIER> FUNCTION> SYSTEM> RSRAMBUP
REBOOT
Reboot of host machine
Lv.2 Details
To reboot the host machine.
Use case
For customization
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
None
DELLNGFL
[Not used]
R-REBOOT
Reboot of host machine: remote
Lv.1 Details
To reboot the host machine by remote control via RUI.
Use case
When rebooting the host machine by remote control
8-160