Download Print this page

Canon imageRUNNER ADVANCE C5051 Series Service Manual page 743

Hide thumbs Also See for imageRUNNER ADVANCE C5051 Series:

Advertisement

COPIER > DISPLAY > DENS
DENS-K-H
Dspl of ATR ctrl Bk-clr TD ratio history
Lv.2 Details
To display the latest 8 Bk-toner density log data (TD ratio) detected
by the ATR Sensor at ATR control.
Sharp change in values may indicate ATR Sensor disconnection/
failure, whereas gradual change in values may indicate failure in
toner supply system.
Use case
When checking toner density in the Developing Assembly at low
density or fogging deterioration
Display/adj/set range
0 to 255
Appropriate target value 80 to 200
SPL-LG-K
Display of Bk toner supply history
Lv.2 Details
To display the latest 8 Bk-toner supply log data.
Each data represents the number of toner blocks supplied per paper.
Use case
When checking the toner supply status at low density or fogging
deterioration
Display/adj/set range
0 to 10
Appropriate target value 0 to 5
8
Service Mode > COPIER > DISPLAY > MISC
T-8-10
8
Service Mode > COPIER > DISPLAY > MISC
■ MISC
COPIER(1)>DISPLAY(1)>MISC(14)(list:7)
ENV-TR
Dspl of secondary transfer environment
Lv.1 Details
To display environment (moisture content) classification used for
secondary transfer ATVC control.
1: Low humidity, 2: Normal humidity, 3: High humidity
Use case
When adjusting the secondary transfer ATVC paper allotted voltage
Display/adj/set range
1 to 3
Appropriate target value 1 to 3
LPOWER-Y
Display of laser light intensity (Y)
Lv.2 Details
To display the Y laser intensity in real-time.
Use case
When analyzing the cause of the image density failure
Display/adj/set range
00 to FF
Appropriate target value 50 to FF
LPOWER-M
Display of laser light intensity (M)
Lv.2 Details
To display the M laser intensity in real-time.
Use case
When analyzing the cause of the image density failure
Display/adj/set range
00 to FF
Appropriate target value 50 to FF
LPOWER-C
Display of laser light intensity (C)
Lv.2 Details
To display the C laser intensity in real-time.
Use case
When analyzing the cause of the image density failure
Display/adj/set range
00 to FF
Appropriate target value 50 to FF
LPOWER-K
Display of laser light intensity (Bk)
Lv.2 Details
To display the Bk laser intensity in real-time.
Use case
When analyzing the cause of the image density failure
Display/adj/set range
00 to FF
Appropriate target value 50 to FF
ITB-POS
Dspl of ITB steering reference position
Lv.1 Details
To display the steering reference position of ITB.
Use case
At initial installation (after execution of COPIER> FUNCTION>
MISC-P> ITB-INIT)
Display/adj/set range
-580 to 580
Unit
pulse
Appropriate target value -300 to 450
Related service mode
COPIER> FUNCTION> MISC-P> ITB-INIT
ITB-POS2
Dspl ITB steering ref position: CL mode
Lv.1 Details
To display the steering reference position of ITB (color mode).
Use case
At initial installation (after execution of COPIER> FUNCTION>
MISC-P> ITB-INIT)
Display/adj/set range
-580 to 580
Unit
pulse
Related service mode
COPIER> FUNCTION> MISC-P> ITB-INIT
8-43
T-8-11
8-43

Advertisement

loading