Download Print this page

Canon imageRUNNER ADVANCE C5051 Series Service Manual page 899

Hide thumbs Also See for imageRUNNER ADVANCE C5051 Series:

Advertisement

■ IMG-FIX
COPIER > OPTION > IMG-FIX
AUTO-DH
ON/OFF of D-max/D-half control
Lv.1 Details
To set ON/OFF of D-max/D-half control at warm-up rotation.
0: D-Max/D-half control is not executed.
1: D-Max/D-Half control is executed only in an HH (high temperature
and high humidity) environment.
2: D-Max/D-Half control is executed in all environments.
Use case
When image smear occurs in an HH environment
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2
0: OFF, 1: ON (HH environment only), 2: ON (all environments)
Default value
1
FX-S-TMP
ITOP control temperature: Plain paper
Lv.1 Details
To set the offset of ITOP control temperature for plain paper (64 to
81 g/m2) at 1/1 speed.
As the value is incremented by 1, the control temperature is
increased by 5 deg C.
Use case
When uneven gloss occurs on the leading edge (94mm) of plain
paper
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: 5 deg C, 2: 10 deg C
Unit
deg C
Default value
0
TMP-TBL2
Fixing control temperature:Heavy paper 1
Lv.1 Details
To set the offset of fixing control temperature for heavy paper 1 (106
to 163 g/m2).
As the value is incremented by 1, the control temperature is
increased by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the
value when fixing offset occurs.
Use case
When offset/fixing failure occurs on heavy paper 1
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default value
0
8
Service Mode > COPIER > OPTION > IMG-FIX
8
Service Mode > COPIER > OPTION > IMG-FIX
COPIER > OPTION > IMG-FIX
TMP-TBL3
Fixing control temperature:Heavy paper 2
Lv.1 Details
To set the offset of fixing control temperature for heavy paper 2 (164
to 209 g/m2).
As the value is incremented by 1, the control temperature is
increased by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the
value when fixing offset occurs.
Use case
When offset/fixing failure occurs on heavy paper 2
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default value
0
TMP-TBL4
Fixing control temperature:Heavy paper 3
Lv.1 Details
To set the offset of fixing control temperature for heavy paper 3 (210
to 256 g/m2).
As the value is incremented by 1, the control temperature is
increased by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the
value when fixing offset occurs.
Use case
When offset/fixing failure occurs on heavy paper 3
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default value
0
TMP-TBL5
Fixing control temperature: Thin ppr
Lv.1 Details
To set the offset of fixing control temperature for thin paper (52 to 63
g/m2).
As the value is incremented by 1, the control temperature is
increased by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the
value when fixing offset occurs.
Use case
When offset/fixing failure occurs on thin paper
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default value
0
8-199