COPIER > DISPLAY > HT-C
DLT-A-C3
ARCDAT scrn A C-density differ (1/3 SPD)
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen A in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-A-K3
ARCDAT scrn A Bk-density differ(1/3 SPD)
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen A in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-B-Y3
ARCDAT scrn B Y-density differ (1/3 SPD)
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen B in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-B-M3
ARCDAT scrn B M-density differ (1/3 SPD)
Lv.2 Details
To display the difference between the M-patch target value and the
current value of screen B in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-B-C3
ARCDAT scrn B C-density differ (1/3 SPD)
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen B in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
8
Service Mode > COPIER > DISPLAY > HT-C
8
Service Mode > COPIER > DISPLAY > HT-C
COPIER > DISPLAY > HT-C
DLT-B-K3
ARCDAT scrn B Bk-density differ(1/3 SPD)
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen B in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-C-Y3
ARCDAT scrn C Y-density differ (1/3 SPD)
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen C in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-C-M3
ARCDAT scrn C M-density differ (1/3 SPD)
Lv.2 Details
To display the difference between the M-patch target value and the
current value of screen C in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-C-C3
ARCDAT scrn C C-density differ (1/3 SPD)
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen C in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
DLT-C-K3
ARCDAT scrn C Bk-density differ(1/3 SPD)
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen C in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023