COPIER > OPTION > FNC-SW
CDS-LVUP
Set to allow CDS periodical update
Lv.1 Details
To set whether to allow the user (administrator) to use the periodical
update function linked with CDS.
When 1 is set, the periodical update function can be used from user
mode.
Use case
When allowing the user to use the periodical update function
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Do not set 1 in Japan. The firmware cannot be updated by user.
Display/adj/set range
0 to1
0: Disabled, 1: Enabled
Default value
The value differs according to the location.
UA-OFFSW
ON/OFF of unified auth function
Lv.1 Details
To set ON/OFF of the Unified Authentication function.
Set the value to 0 when not preferring to use the Unified
Authentication function because of security concern.
Use case
Upon user's request (not to use the Unified Authentication function)
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: ON, 1: OFF
Default value
0
MIB-NVTA
RFC-compatible character stringMIB write
Lv.1 Details
As default, MIB object which NVT-ASCII can be written exists in
order to link with LUI entry value. This violates RFC order, so a
problem like garbled 2-byte characters may occur in the SNMP
monitoring system, such as the 3rd vendor's MPS.
Whether non-RFC-compatible character strings are written in MIB
can be set using this mode.
When 1 is set, only the character strings which are strictly compatible
with RFC are written. (Writing operation is executed from the SNMP
manager.) LUI is not linked.
Use case
Upon user's request (operation with RFC-compatible system)
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 3
0: Compatible in a conventional manner, 1: RFC-compatible, 2 to 3:
Not used
Default value
0
MIB-EXT
[Not used]
8
Service Mode > COPIER > OPTION > FNC-SW
8
Service Mode > COPIER > OPTION > FNC-SW
COPIER > OPTION > FNC-SW
SVC-RUI
Enabling of RUI function for servicing
Lv.1 Details
To set whether to enable the RUI function for servicing (not provided
to end users).
When 0 is set, the RUI function is disabled.
When setting the value other than 0, RUI function is enabled. The
value entered becomes password to use the RUI function.
The data is cleared after the main power switch is turned OFF/ON.
Use case
When preferring to use the import function of background image file
of main menu
Adj/set/operate method Enter the setting value, and then press OK key.
The data is cleared after the main power switch is turned OFF/ON.
Display/adj/set range
0 to 65535
Default value
0
LCDSFLG
Enabling of local CDS server
Lv.1 Details
To set whether to use the local CDS server.
When CDSFIRM is 1, this setting is enabled.
Use case
When using the local CDS server
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When CDSFIRM is 1, this setting is enabled.
Display/adj/set range
0 to 1
0: Disabled, 1: Enabled
Default value
0
Related service mode
COPIER > OPTION > FNC-SW > CDSFIRM
BXSHIFT
Setting of binding at 0mm binding margin
Lv.1 Details
To set whether to judge the job as a job "without binding" when
storing a PDL job in Inbox while the binding margin is set to "0".
By setting the binding margin to 0 mm while "0" is set, the job is
processed as "without binding". "Booklet" in "Options" on the Inbox
screen can be also used.When "1" is set, it is judged as "with
binding" even the binding margin is 0 mm so "Booklet", which has an
exclusive relationship with "binding", cannot be used.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
When storing a PDL job in Inbox while 1 is set, "Booklet" in "Options"
on the Inbox screen cannot be used.
Display/adj/set range
0 to 1
0: Without binding, 1: With binding
Default value
0