COPIER > ADJUST > HV-TR
2TR-P1
Sec trn ATVC ppr allot V: crd 1st,L-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 1st side of postcard in
secondary transfer ATVC control at low humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
2TR-P2
Sec trn ATVC ppr allot V: crd 2nd,L-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 2nd side of postcard in
secondary transfer ATVC control at low humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
2TR-H1
Sec trn ATVC ppr allot V:hvy1 1st,L-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 1st side of heavy paper 1
in secondary transfer ATVC control at low humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
8
Service Mode > COPIER > ADJUST > HV-TR
8
Service Mode > COPIER > ADJUST > HV-TR
COPIER > ADJUST > HV-TR
2TR-H2
Sec trn ATVC ppr allot V:hvy1 2nd,L-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 2nd side of heavy paper 1
in secondary transfer ATVC control at low humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
2TR-UH1
Sec trn ATVC ppr allot V:hvy3 1st,L-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 1st side of heavy paper 3
in secondary transfer ATVC control at low humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
2TR-UH2
Sec trn ATVC ppr allot V:hvy3 2nd,L-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 2nd side of heavy paper 3
in secondary transfer ATVC control at low humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0