Download Print this page

Canon imageRUNNER ADVANCE C5051 Series Service Manual page 376

Hide thumbs Also See for imageRUNNER ADVANCE C5051 Series:

Advertisement

4
Parts Replacement and Cleaning > Image Formation System > Pulling Out the Process Unit > Procedure
Removing the Recycle Toner Bottle
■ Preparations
1) Open the Front Cover.
■ Procedure
1) Release the Recycle Toner Bottle Lock Lever.
2) Remove the Recycle Toner Bottle.
CAUTION:
Do not tilt the Recycle Toner Bottle.
(Because it may cause misdetection on the Full Detection Sensor.)
4
Parts Replacement and Cleaning > Image Formation System > Pulling Out the Process Unit > Procedure
F-4-162
F-4-163
Pulling Out the Process Unit
■ Preparations
1) Open theRight Lower Cover and Right Upper Cover.
2) Open the Front Cover.
3) Remove the ITB Cover.
■ Procedure
1) Make sure that the arrow of ITB Sub Pressure Release Lever is aligned with the triangle
mark of the plate.
(If it is not aligned, align the arrow of lever with the triangle mark of plate.)
Triangle mark
ITB sub pressure
release lever
4-110
Triangle mark
ITB sub pressure
release lever
4-110
F-4-164

Advertisement

loading