Download Print this page

Canon imageRUNNER ADVANCE C5051 Series Service Manual page 815

Hide thumbs Also See for imageRUNNER ADVANCE C5051 Series:

Advertisement

■ HV-TR
COPIER > ADJUST > HV-TR
1TR-TGY
Adj of prmry trns ATVC Y target current
Lv.2 Details
To adjust the target current for the Y-color primary transfer current.
Increase the value when low-voltage mottled image occurs with
Y-color.
Decrease the value when Y-color fogging occurs (especially in the 94
mm portion of the image leading edge).
Use case
When an image failure due to the primary transfer occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-50 to 50
Unit
uA
Default value
0
1TR-TGM
Adj of prmry trns ATVC M target current
Lv.2 Details
To adjust the target current for the M-color primary transfer current.
Increase the value when low-voltage mottled image occurs with
M-color.
Decrease the value when M-color fogging occurs (especially in the
94 mm portion of the image leading edge).
Use case
When an image failure due to the primary transfer occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-50 to 50
Unit
uA
Default value
0
1TR-TGC
Adj of prmry trns ATVC C target current
Lv.2 Details
To adjust the target current for the C-color primary transfer current.
Increase the value when low-voltage mottled image occurs with
C-color.
Decrease the value when C-color fogging occurs (especially in the
94 mm portion of the image leading edge).
Use case
When an image failure due to the primary transfer occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-50 to 50
Unit
uA
Default value
0
8
Service Mode > COPIER > ADJUST > HV-TR
8
Service Mode > COPIER > ADJUST > HV-TR
COPIER > ADJUST > HV-TR
1TR-TGK1
Pry trns ATVC Bk target current: 1-clr
Lv.2 Details
To adjust the target current for the Bk-color primary transfer current.
Increase the value when low-voltage mottled image occurs with Bk-
color.
Decrease the value when Bk-color fogging occurs (especially in the
94 mm portion of the image leading edge).
Use case
When an image failure due to the primary transfer occurs in black
mode
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-50 to 50
Unit
uA
Default value
0
2TR-N1
Sec trn ATVC ppr allot V:pln1 1st,L-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 1st side of plain paper 1
in secondary transfer ATVC control at low humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
2TR-N2
Sec trn ATVC ppr allot V:pln1 2nd,L-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 2nd side of plain paper 1
in secondary transfer ATVC control at low humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0