COPIER > FUNCTION > INSTALL
INISET-C
Exe of C Dev Ass'y initial install mode
Lv.1 Details
To automatically execute operation necessary for initial installation of
the C Developing Assembly.
1. Idle rotation of the Developing Assembly
2. Initialization of the Toner Density Sensor
3. Secondary transfer ATVC control
4. Patch light intensity correction
5. Background correction
6. Discharge current control
7. Primary transfer ATVC control
8. Initialization of the Patch Sensor
9. Auto registration
10. D-max control
11. D-half control
12. ARCDAT-Lite (creation of target)
13. Cleaning of the Secondary Transfer Roller twice
14. Counter reset of the Developing Assembly
Use case
When replacing the C Developing Assembly
Adj/set/operate method Select the item, and then press OK key.
Caution
- When installing the machine or replacing the Developing Assembly
of other color, do not use this item.
Display/adj/set range
During operation: xxx second (remaining time), At normal termination:
OK, At abnormal termination: NG
Required time
155 sec
Related service mode
COPIER> FUNCTION> INSTALL> INISET-Y, INISET-M, INISET-K,
INISET-4
AINR-OFF
[Not used]
E-RDS
Set use/no use of Embedded-RDS function
Lv.1 Details
To set whether to use the Embedded-RDS function.
Use case
When using Embedded-RDS
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
0 to 1
0: Not used, 1: Used (All the counter information is sent.)
Default value
0
Related service mode
COPIER> FUNCTION> INSTALL> RGW-PORT, COM-TEST, COM-
LOG, RGW-ADR
8
Service Mode > COPIER > FUNCTION > INSTALL
8
Service Mode > COPIER > FUNCTION > INSTALL
COPIER > FUNCTION > INSTALL
RGW-PORT
Set port number of Sales Co's server
Lv.1 Details
To set the port number of the sales company's server to be used for
Embedded-RDS.
Use case
When using Embedded-RDS
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
1 to 65535
Default value
443
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, COM-TEST, COM-LOG,
RGW-ADR
COM-TEST
Dis connect result w/ Sales Co's server
Lv.1 Details
To display the result of the connection test with the sales company's
server.
Use case
When using Embedded-RDS
Adj/set/operate method Select the item, and then press OK key.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
During operation: ACTIVE, When connection is completed: OK,
When connection is failed: NG
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-LOG,
RGW-ADR
COM-LOG
Dis connect error w/ Sales Co's server
Lv.1 Details
To display error information when the connection with the sales
company's server failed.
Use case
When using Embedded-RDS
Adj/set/operate method Display only
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
Year, date, time, error code, error detail information (maximum 128
characters)
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST,
RGW-ADR
RGW-ADR
URL setting of Sales Company's server
Lv.1 Details
To set the URL of the sales company's server to be used for
Embedded-RDS.
Use case
When using Embedded-RDS
Adj/set/operate method 1) Select the URL.
2) Enter the URL, and then press OK key.
Caution
- Do not use Shift-JIS character strings.
- Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
URL
Default value
https://a01.ugwdevice.net/ugw/agentif010
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST,
COM-LOG
8-139
8-139