CHAPTER 25 LOW-VOLTAGE DETECTOR
(2) When used as interrupt
Check that "supply voltage (V
) > detection voltage (V
)" in the servicing routine of the LVI interrupt by using bit
DD
LVI
0 (LVIF) of the low-voltage detection register (LVIM). Clear bit 0 (LVIIF) of interrupt request flag register 0L (IF0L)
to 0 and enable interrupts (EI).
In a system where the supply voltage fluctuation period is long in the vicinity of the LVI detection voltage, wait for
the supply voltage fluctuation period, check that "supply voltage (V
) > detection voltage (V
)" using the LVIF
DD
LVI
flag, and then enable interrupts (EI).
*
491