TEMPerature Sub-Register

This shows whether the temperature of critical components is near or over the
maximum operating temperature.
Table 4.19 TEMPerature Sub-Register
Bit

Standard Event Status Register

The standard event status register sets bits for specific events during power supply
operation. All bits in the standard event status registers are set through the error event
queue. The register is defined by 488.2 and is controlled using 488.2 common
commands, *ESE, *ESE?, and *ESR?.
Figure 4.6 summarizes the standard Event Status Register
Figure 4.6 IEEE 488.2 Status Register and Status Byte
Release 3.0
Bit Weight
Bit Name
0
1
Over TEMperature Set if the power supply temperature
1
2
High TEMperature Set if the power supply temperature
Operation Complete
Not Used
Query Error
Device Dependent Error
Execution Error
Command Error
User Request
Power On
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Standard Event Status Register
Standard Event Status Register
Description
exceeds the maximum operating
temperature.
exceeds 90% of the maximum
operating temperature.
0
1
2
3
4
5
Summary of QUESTionable Status
6
7
+
8
9
10
11
12
13
14
15
Remote Operation
SCPI Commands for Digital Interfaces
Not Used
Not Used
Not Used
MAV
RQS/MSS
Summary of OPERation Status
Status Byte
0
1
2
3
4
5
6
7
153