  DANGER
[4]

OCC ASSEMBLY

4-1. Replacing the OCC Assembly

(1) Remove the SEMS cap bolt
(2) The camera assembly is secured with the SEMS cap bolts
with the SEMS cap bolts
camera and light assemblies.
(3) Reassemble the components in the reverse order of disassembly.
(4) After the camera assembly has been replaced, it is absolutely necessary to adjust the focus
and input the MS parameters. After the light assembly has been replaced, it is necessary to
adjust OCC light. (See 4-7, List of Readjustment Items After Replacement.)
  SEMS cap bolts (× 4)
1
 
SEMS cap bolts (× 3)
Camera bracket D
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
 
adjustment work.
to detach the camera bracket D.
. Disconnect the connectors and remove relevant bolts to detach the
Figure 4-1-1 OCC Assembly
and the light assembly is secured
4-1
XM-base
Camera assembly
3 SEMS cap bolts (× 2)
Light assembly
 
Rev. 2.00