Xy-Axis Driver Indication Display; Scale I/F Unit - JUKI FX-1 Maintenance Manual

High-speed modular mounter
Table of Contents

Advertisement

FX-1/FX-1R Maintenance Manual

13-5-2. XY-Axis Driver Indication Display

An indication display showing the status is mounted on the front of the XY-driver.
Normally, this indication shows the status as shown in the following.
LED indication
LED 表示
Contents
During initialization
内容
イニシャライズ中

13-5-3. Scale I/F Unit

Four scale I/F units (or five scale I/F units in case of FX-1R) are mounted on the right side of the
XY-driver.
The axis names are the YBL-, YBR-, XL-, and XR-axis from the left end when viewed from the front
of the machine.
In case of FX-1R, the axis names are the YA-, YBL-, YBR-, XL-, and XR-axis.
Servo amplifier
XL, XR
YBL, YBR
CN1A
Connected to the SCALE-I/F PCB.
CN1B
Connected to the motor encoder
(YB-axis only)
CN2
Connected to the servo amplifier.
Ab
C#
Servo OFF
サーボオフ
# shows an axis No. (For details, see the table on the right.)
#には軸番号が表示される (右表を参照
SW1 setting
LINEAR
CLOSE
FX-1
D#
Servo ON
サーボオン
* YA is for FX-1R only.
Connected to the SCALE PCB.
Connected to the motor encoder (X-axis
is not connected).
Connected to the servo amplifier.
13-23
XL軸
1
XL-axis
XR軸
2
XR-axis
YBL軸
3
YBL-axis
YBR軸
4
YBR-axis
YA軸
1
YA-axis
FX-1R