Led Indications - JUKI FX-1 Maintenance Manual

High-speed modular mounter
Table of Contents

Advertisement

FX-1/FX-1R Maintenance Manual

13-6-2. LED Indications

Ten LEDs are mounted on the 4-axis integral amplifier.
These LEDs show the operating status of the 4-axis integral amplifier as shown below.
No. LED name Function
1
CHARGE Lights up if electric charge exists in the main power supply.
Do not joint the electric wire when this LED is lit.
2
SRD
Lit when the control power (DC5V) is supplied correctly.
3
RD1
Shows the status of the 1st axis.
Flashing in green: Servo OFF status
Lit in green: Servo ON status
4
AL1
Shows the status of the 1st axis.
Flashing in red: Warning status
Lit in red: Alarm status
5
RD2
Shows the status of the 2nd axis.
Flashing in green: Servo OFF status
Flashing in red: Warning status
6
AL2
Shows the status of the 2nd axis.
Flashing in red: Warning status
Lit in red: Alarm status
7
RD3
Shows the status of the 3rd axis.
Flashing in green: Servo OFF status
Lit in green: Servo ON status
8
AL3
Shows the status of the 3rd axis.
Flashing in red: Warning status
Lit in red: Alarm status
9
RD4
Shows the status of the 4th axis.
Flashing in green: Servo OFF status
Lit in green: Servo ON status
10
AL4
Shows the status of the 4th axis.
Flashing in red: Warning status
Lit in red: Alarm status
AL4 AL3 AL2 AL1
RD4
RD3
13-26
RD2
RD1
CHARGE
SRD