DANGER
[4]
OCC ASSEMBLY
4-1. Replacing the OCC Assembly
(1) Remove the SEMS cap bolts
(2) The camera assembly has been secured with the SEMS cap bolts
assembly has been secured with the SEMS cap bolts
Disconnect the connectors and remove relevant mounting screws, and then replace the
camera assembly.
(3) Reassemble the components in the reverse order of disassembly.
(4) After the camera assembly has been replaced, adjust the focus and input the MS
parameters.
After the light assembly has been replaced, adjust the OCC light. (See also section 4-8, List
of Readjustment Items After Replacement.)
SEMS cap bolts
( 4)
Head screws
( 1)
SEMS cap bolts
( 3)
Maintenance Guide
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
adjustment work.
, the head screws
Figure 4-1-1 OCC Assembly
4-1
and detach the camera.
.
Head plate
Camera assembly
SEMS cap bolts
( 2)
Light assembly
while the light