FX-1/FX-1R Maintenance Manual
(5) Adjust the sensor dog position
When opened. → The OPEN sensor is turned ON at a position where is 1 mm before the slide
When closed. → The CLOSE sensor is turned ON at a position where is 1 mm before the
Note 1) After the position has been adjusted, fix the sensor dog with the SEMS cap bolt.
Note 2) The nut must be tightened with a torque of 1.3 N
plate is opened.
slide plate is closed.
1mm
Figure 7-1-3 Adjustment of the Sensor Dog
m.
Sensor detection
position
7-3
SEMS cap bolt
Sensor dog
Sensor
Rev. 2.00