Y-Axis Magnescale Affixing Position (For Fx-1R, See Section 1-8-2.); Gap Of Magnescale (For Fx-1R, See Section 1-8-4.) - JUKI FX-1 Maintenance Manual

High-speed modular mounter
Table of Contents

Advertisement

FX-1/FX-1R Maintenance Manual

1-4-2. Y-axis Magnescale Affixing Position (For FX-1R, see Section 1-8-2.)

(1) Affix the magnescale with the 1.5mm-thick block gauge made tightly in contact with the side
surface of the Y-linear guide.
MAGNESCALE (Y-AXIS)
L902E121000

1-4-3. Gap of Magnescale (For FX-1R, see Section 1-8-4.)

(1) Loosen the screw fixing the sensor and put the 0.8mm-thick tool in the gap between the
magnescale and sensor head.
(2) Tighten the screw and remove the 0.8mm-thick tool.
Figure 1-4-3-1 (Y-axis)
Block gauge
Figure 1-4-2-1
Figure 1-4-3-2 (X-axis)
1-7
Rev. 2.00