8-9. Replacing the Roller Lever (Optional Replacement Table)

Before replacing the roller lever, always shut-down the main compressed air.
The following figure (Figure 8-9-1) shows the machine with the FR (front right) and RL (rear left)
specifications.
In the machine with the FL (front left) and RR (rear right) specifications, the silencer is mounted at
the position opposite to the position shown in the figure.
Flat head screw,
M4 × 25
Elbow union
Silencer
Figure 8-9-1
8-10