FX-1/FX-1R Maintenance Manual

5-7. Replacing the IN and OUT Sensors

Bind the cables A and B with binding bands, taking care that they are not pulled or loosened
excessively during adjustment of sensor position.
Right-side sensor
L828E8210A0
L832E3210A0
SL4031291SC
EA9500B0000
<Adjusting the sensitivity>
Make an adjustment so that a (matte) black glass epoxy PWB placed on the transport path can be
detected. Place a (matte) black glass epoxy PWB under the sensor and rotate the sensitivity
adjustment knob of the sensor counterclockwise. Then gradually rotate it clockwise up to the
position at which the specified PWB is detected.
Figure 5-7-1
IN SENSOR ASM
OUT SENSOR ASM
SCREW
CABLE_BAND
5-9
Left -side sensor
Rev. 2.00