FX-1/FX-1R Maintenance Manual
Set the adjustment screw to the center between positions A and B.
Position A
MIN
(5) Perform the fine adjustment of the sensor position.
Select [Manual Control] and [Individual Transfer Control] in that order to turn ON the
stopper and raise the stopper.
With manual operation, gradually load a PWB. Move the sensor position so that the
distance from the sensor ON position to the stopper tip becomes dimension "a"
(25±1mm).
Position B
MAX
MIN
Figure 5-9-2
Figure 5-9-3
5-13
Set position
MAX
MIN
MAX
Rev. 2.00