Magnescale Detector (Used In Fx-1; Not Used In Fx-1R) - JUKI FX-1 Maintenance Manual

High-speed modular mounter
Table of Contents

Advertisement

FX-1/FX-1R Maintenance Manual

13-5-4. Magnescale detector (Used in FX-1; not used in FX-1R)

 
TSC6185-01-1120 8S Connector (Female)
Made by Hosiden.
Mounting screw at 4 locations
4-M5 tapping (M4 bolt mounting hole)
The following shows the assignment of each axis.
HEAD1: XL-axis, HEAD2: XR-axis, HEAD3: YBL-axis, HEAD4: YBR-axis
When the LED is lit in green, this shows that the scale input is correct. On the contrary, when the
LED is lit in red, this shows that the scale input is incorrect.
13-24
Rev. 2.00