HEAD UNIT
2-1. Replacing and Adjusting the Head
2-1-1. MNLA Head
(1) Detach the head top cover
(2) Shut down the main air pressure to the machine main unit and disconnect the air tubes from
the half union and elbow union.
Head top cover
Elbow union
(3) Remove the head sensor PWB cover and disconnect the cable connector from the head sensor
board. Disconnect the motor connector from the Zθ-servo amplifier board.
Head sensor PWB cover
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
adjustment work.
. (4 mounting screws)
Figure 2-1-1
Figure 2-1-2
2-1
Half union
Rev. 2.00