JUKI FX-1 Maintenance Manual page 167

High-speed modular mounter
Table of Contents

Advertisement

FX-1/FX-1R Maintenance Manual
Use the switch 1 to set the function Rev. and pattern Rev. of the board. The following figure
shows the assignment and weight of each bit. The setting shown in this figure means that the
function Rev. is set at "02" and the pattern Rev. is set at "02".
ON
SW1
OFF
1
[Meaning of LED]
5 LEDs are mounted on the SAFETY board and have the following meanings.
ALM
LED 1
LED 1: Lights up if activation of the YA-limit sensor, YB-limit sensor, or emergency stop switch is detected.
COSW
LED 2
LED 2: Lights up if the cover open is detected.
AREA−F
LED 3: Not used.
LED 3
LED 4: Not used.
AREA−R
LED 4
LED 5: Lights up if the activation of the feeder float sensor is detected.
F−FLOT
LED 5
 
[Adjustment items after replacement]
After the replacement has been completed, it may be required to back up the MS parameters.
From the menu bar, select [File] and [Control Data Management] to back up the MS parameters.
8
0
2
1
2
機能Rev.設定
Function Rev. setting
2
2
3
2
0
2
1
Pattern Rev. setting
2
パターンRev.設定
2
2
3
2
YA軸リミット、YB軸リミット、非常停止が検出された場合に点灯
カバーオープンが検出された場合
使用し
ない
使用し
ない
フィーダ浮きセンサが検出された場合に点灯
13-13
に点灯