FX-1/FX-1R Maintenance Manual

9-2. Replacing the Filter Element

(1) Turn the filter element main unit 45° clockwise or counterclockwise to pull it out downward
while lowering the slide part.
(2) When replacing the filter element B on the air filter side, turn the resin part fixing the filter
element B counterclockwise to detach it.
(3) When replacing the filter element A on the mist separator side, turn the filter element A
counterclockwise to detach it.
(4) Reassemble the components in the reverse order of disassembly.
<CAUTION>
Before replacing the filter element, always close the knob of the finger valve.
The filter element must be replaced when it has been used for two years or when
pressure drop reaches 0.1 MPa (1kgf/cm
PF901002000
Filter element A
Mist separator
2
).
Air filter
PF901006000
Filter element B
Resin part
Slide part
9-2