General Troubleshooting
4-16
Test
Control Panel Display
Dial tone Min
(10ms)
Dial tone Max
(10ms)
CNG Stop
Select
G3M TX Cable
EQU
G3M RX Cable
EQU
G3M V34 Bit
Rate
Capability V34
G3M TX
Coding
G3M RX
Coding
BackUp Data
NOTE:
The system data initialization does not initialize data on EEPROM
(except dial types and country codes). The counter clear does not clear
scan counter clearance on EEPROM; it only clears counters on SRAM.
Test Description
Sets the minimum limit of dial tone
pattern detection duration.
Sets the maximum limit of dial tone
pattern detection duration.
Sets the conditions for stopping CNG
transmission. Conditions :
CED&V21: When CED and V.21
preamble are detected.
CED: When CED is detected.
V21: When V.21 preamble is
detected.
Sets the cable amplitude equalizer
value for transmission. These values
are available:
0db Equal to a cable length of 0km.
4db Equal to a cable length of 1.9km
8db Equal to a cable length of 3.6km
12db Equal to a cable length of
7.2km
Sets the cable amplitude equalizer
value for reception (applicable to
V17, V29, and V27ter) These values
are available:
0db Equal to a cable length of 0km.
4db Equal to a cable length of 1.9km
8db Equal to a cable length of 3.6km
12db Equal to a cable length of
7.2km
Sets the signaling rate for the Super
G3 (V34) mode. Values range from
2400bps to 33600bps in 14 steps.
2400/4800/7200/9600/12000/
14400/16800/19200/21600/24000/
26400/28800/31200/33600
Sets the communication capability
of the Super G3 (V34) mode.
Sets the data encoding method for
transmission. When the encoding
method set here is not supported by
the receiving side, the receiving
side's method is adopted. Available
methods: are MH/MR/ MMR/JBIG
Sets the data encoding method for
reception. Available methods: are
MH/MR/ MMR/JBIG