Error Messages and Codes
Imaging Unit Life, Replace Imaging Unit Error
Applicable Errors
Initial Actions
3-70
The Imaging Unit is near, or has reached, end of life..
•
Imaging Unit Life
•
Replace Imaging Unit
•
Check the Imaging Unit life counter.
•
Check that the correct Imaging Unit is installed for this model.
•
Remove and reseat the Imaging Unit.
•
Cycle system power.
•
If the problem persists, follow the procedure below.
Troubleshooting Reference Table
Applicable Parts
Imaging Unit PL4.1.21
MCU Board, PL10.7.7
Troubleshooting Procedure Table
Step
Actions and Questions
1
Replace the Imaging Unit
(page 8-8).
NOTE
Remove the 8 sealing tapes from
the new Imaging Unit before
installation.
Does the error persist?
Wiring and Plug/Jack Map References
"Map 1 - MCU Board" on page 10-6
"Xerographics" on page 10-18
Yes
No
Replace the
Complete.
MCU Board
(page 8-57)..