Service Parts Disassembly

Registration Roller

PL3.2.9
8-30
4. Release 3 hooks that secure the Registration Sensor to the Feeder Assembly
and remove the sensor.
5. Disconnect P/J232 from the Registration Sensor.
1. Remove the Upper Frame Assembly (page 8-68).
Caution
The Registration Actuator Out is spring-loaded by a small spring located
under the actuator.
2. Release the hook on the Registration Actuator Out and shift the Registration
Roller Actuator to the right side.