Error Messages and Codes
Invalid Job Error
Applicable Error
Initial Actions
3-88
Troubleshooting Procedure Table
Step
Actions and Questions
1
Check the User Registration value
under the Print Auditron setting.
Maximum value is 50.
Has the user count exceeded the
setting?
2
Reseat the Image Processor Board
connections.
Cycle system power.
Does the error persist?
Print job settings do not match media size/type settings for the source. The
following troubleshooting procedure applies to this error.
•
016-799: Invalid Job Error
•
Check the media size settings for the print job and source.
•
Reseat installed memory.
•
Cycle printer power.
•
If the problem persists, follow the procedure below.
Troubleshooting Reference Table
Applicable Parts
Image Processor Board, PL10.6.6
Troubleshooting Procedure Table
Step
Actions and Questions
1
Print a small size file.
Does the error persist?
Yes
No
Reset the count
Go to step 2.
to 50 or less.
Replace the I/P
Complete.
Board
(page 8-41).
Wiring and Plug/Jack Map References
"Map 3 - Electrical and Drive" on page 10-8
Yes
No
Go to step 2.
Complete.
Phaser 6128MFP Service Manual