Configuring SIMOTION D410
3.3 Configuring the PROFIBUS DP interface (only D410 DP)
3.3.3

Operating SIMOTION D410 on PROFIBUS DP.

PROFIBUS DP interface (X21)
SIMOTION D410 provides an interface for connecting to PROFIBUS DP. The interface
supports transmission rates up to 12 Mbit/s.
The X21 interface can be operated as a:
● DP slave, isochronous
● DP master, isochronous
● DP slave, not isochronous
● DP master, not isochronous
● MPI interface
Both PROFIBUS DP interfaces are set by default for operation as master at address 2 at a
transmission rate of 1.5 Mbit/s. The PROFIBUS DP network is automatically detected and
generated for this setting.
However, you can select other settings. Such user-specific settings must be configured in
HW Config and NetPro.
Note
Communication with the SINAMICS Integrated of a D410 is always equidistant. Here, the
SIMOTION D410 is the master and the SINAMICS Integrated drive is the slave.
44
D410
Commissioning Manual, 05/2009