Testing The Configured Axis Using The Axis Control Panel - Siemens SIMOTION D410 Series Commissioning Manual

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

Commissioning (software)

4.7 Testing the configured axis using the axis control panel

4.7
Testing the configured axis using the axis control panel
Axis control panel
The axis control panel is used exclusively for testing axes.
You can use the axis control panel for the following tasks, for example:
● Testing all system components before the axis movement is controlled by a program
● Testing as to whether you can move the axis using the axis control panel if a fault is
● Moving the axes for tuning purposes (controller tuning)
● Executing active homing
● Setting and resetting the axis enable signal
● Testing a connected axis
Prerequisites
Prerequisites for testing:
● The project has been downloaded to the target system.
● SIMOTION SCOUT is in online mode.
● The mode selector switch is at STOPU:
Axis test
1. Open the "AXES" folder in the Project Navigator and click the "Control panel" entry below
Figure 4-22
Axis control panel
2. To display the control range and axis diagnostics, click the "Show/hide control range" and
90
detected
Recommendation: Operate the mode selector switch via SIMOTION SCOUT only
("Target system" > "Control operating mode").
the axis (for example, Axis_1).
The axis control panel is displayed.
"Show/hide diagnostics area" buttons.
D410
Commissioning Manual, 05/2009

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 pnSimotion d410 dp

Table of Contents