Restoring The Default Settings Of Sinamics Integrated; Restoring The Default Settings Of Simotion D410 - Siemens SIMOTION D410 Series Commissioning Manual

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

Commissioning (software)
4.14 Deleting data
4.14.4

Restoring the default settings of SINAMICS Integrated

Prerequisite
You must be online to SINAMICS Integrated in order to restore its default settings.
Restoring the default settings
1. Right-click "SINAMICS_Integrated" in the Project Navigator.
2. Select the "Target device > Restore default settings" command from the shortcut menu.
This restores the delivery state of SINAMICS Integrated.
4.14.5

Restoring the default settings of SIMOTION D410

Overview
SIMOTION D410 is supplied with default parameters such as the transmission rate or
PROFIBUS addresses. You can restore the default settings using the DIL switch. This
deletes the following data:
● Non-volatile data in the SIMOTION device
● The backup copy of non-volatile data on the CompactFlash Card
● User data in the "volatile data" area and on the CompactFlash Card
● The communication configuration (IP and DP parameters) on the CompactFlash Card is
All licenses on the CompactFlash Card are retained.
134
(PMEMORY.XML/PMEMORY.BAK)
set to the factory settings.
D410
Commissioning Manual, 05/2009