Basic Measures For Protection Against Discharge Of Static Electricity - Siemens SIMOTION D410 Series Commissioning Manual

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

B.3

Basic measures for protection against discharge of static electricity

Ensure sufficient grounding
When working with electrostatic sensitive devices, make sure that the you, your workstation,
and the packaging are properly grounded. This prevents the accumulation of static
electricity.
Avoid direct contact
You should only touch ESD components if unavoidable (for example, during maintenance
work). When you touch modules, make sure that you do not touch either the pins on the
modules or the printed conductors. If you follow these instructions, electrostatic discharge
cannot reach or damage sensitive components.
If you have to take measurements on a module, make sure that you first discharge any static
that may have accumulated in your body. To do this, touch a grounded metal object. Only
use grounded measuring instruments.
D410
Commissioning Manual, 05/2009
B.3 Basic measures for protection against discharge of static electricity
ESD guidelines
191

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 pnSimotion d410 dp

Table of Contents