Commissioning (software)

4.8 Integrating additional encoders (optional)

4.8
Integrating additional encoders (optional)
4.8.1

General information

SIMOTION D410 provides the option of integrating and configuring further encoders in
addition to the motor encoder.
The following encoders are supported for operation with SIMOTION D410:
● Encoders with DRIVE-CLiQ interface
● Encoders connected to SIMOTION D410 via the onboard encoder interface (X23)
● Encoders connected to SIMOTION D410 using an SMx module
● Encoders connected using PROFIBUS or PROFINET
Prerequisite
SIMOTION D410 features a DRIVE-CLiQ X100 interface for connecting an encoder. An
additional encoder can be connected, for example, using the on-board encoder interface
(X23).
Configuring two encoders
The second encoder can be used at SIMOTION D410, for example, as:
● A machine encoder (second encoder = direct measuring system)
● An external encoder
Configuring tasks
Encoders connected via PROFIBUS or PROFINET are configured for SIMOTION only.
Encoders connected using SMx, DRIVE-CLiQ or the onboard encoder interface, must be
configured for the drive (SINAMICS Integrated) and SIMOTION.
Configure this additional encoder on drive side (SINAMICS Integrated) and in SIMOTION:
1. For information on configuring a second encoder on the SINAMICS drive, refer to the
2. For information on configuring a second encoder for a TO axis in SIMOTION, refer to the
3. For information on configuring an external encoder in SIMOTION, refer to the section
These steps in configuring are described in the next section.
92
A direct measuring system measures the technological parameter directly, i.e. without the
interference of influences such as torsion, backlash, slip, etc.
This may enable improved smoothing of mechanical influences. If you use a second
encoder as a machine encoder, you can work with the encoder changeover function.
You can use the external encoder for recording an external master value, for example.
section titled Configuring a second encoder on the SINAMICS drive (Page 93).
section titled Configuring a second encoder for a TO axis in SIMOTION (Page 94).
titled Configuring external encoders in SIMOTION (Page 94).