Parameter Descriptions
[37]
Control word
bit 12
[40]
Out of ref
range
[41]
Below
reference low
4
4
[42]
Above
reference high
[45]
Bus Ctrl
[46]
Bus Ctrl On at
timeout
[47]
Bus Ctrl Off at
timeout
[55]
Pulse output
[56]
Heat sink
cleaning
warning, high
[60]
Comparator 0
[61]
Comparator 1
[62]
Comparator 2
[63]
Comparator 3
[64]
Comparator 4
[65]
Comparator 5
[70]
Logic Rule 0
[71]
Logic Rule 1
[72]
Logic Rule 2
[73]
Logic Rule 3
62
®
VLT
AutomationDrive FC 360
This option is active when the actual
speed is outside the settings in
parameter 4-54 Warning Reference Low to
parameter 4-55 Warning Reference High.
This option is active when the actual
speed is below the speed reference
setting.
This option is active when the actual
speed is above the speed reference
setting.
Controls output via fieldbus. The state of
the output is set in parameter 5-90 Digital
& Relay Bus Control. The output state is
retained in the event of fieldbus timeout.
Controls output via fieldbus. The state of
the output is set in parameter 5-90 Digital
& Relay Bus Control. When bus timeout
occurs, the output state is set high (On).
See parameter group 13-1* Comparators. If
comparator 0 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group 13-1* Comparators. If
comparator 1 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group 13-1* Comparators. If
comparator 2 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group 13-1* Comparators. If
comparator 3 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group 13-1* Comparators. If
comparator 4 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group 13-1* Comparators. If
comparator 5 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group 13-4* Logic Rules. If
logic rule 0 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group 13-4* Logic Rules. If
logic rule 1 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group 13-4* Logic Rules. If
logic rule 2 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group 13-4* Logic Rules. If
logic rule 3 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
Danfoss A/S © 06/2017 All rights reserved.
[74]
Logic Rule 4
See parameter group 13-4* Logic Rules. If
logic rule 4 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[75]
Logic Rule 5
See parameter group 13-4* Logic Rules. If
logic rule 5 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
[80]
SL Digital
See parameter 13-52 SL Controller Action.
Output A
The output goes high whenever the
smart logic action [38] Set dig. out. A high
is executed. The output goes low
whenever the smart logic action [32] Set
dig. out. A low is executed.
[81]
SL Digital
See parameter 13-52 SL Controller Action.
Output B
The input goes high whenever the smart
logic action [39] Set dig. out. B high is
executed. The input goes low whenever
the smart logic action [33] Set dig. out. B
low is executed.
[82]
SL Digital
See parameter 13-52 SL Controller Action.
Output C
The input goes high whenever the smart
logic action [40] Set dig. out. C high is
executed. The input goes low whenever
the smart logic action [34] Set dig. out. C
low is executed.
[83]
SL Digital
See parameter 13-52 SL Controller Action.
Output D
The input goes high whenever the smart
logic action [41] Set dig. out. D high is
executed. The input goes low whenever
the smart logic action [35] Set dig. out. D
low is executed.
[160] No alarm
The output is high when no alarm is
present.
[161] Running
The output is high when the frequency
reverse
converter is running counterclockwise
(the logical product of the status bits
Running AND Reverse).
[165] Local reference
active
[166] Remote ref
active
[167] Start command
The output is high when there is an
active
active start command, and no stop
command is active.
[168] Drive in hand
The output is high when the frequency
mode
converter is in hand-on mode.
[169] Drive in auto
The output is high when the frequency
mode
converter is in auto-on mode.
[170] Homing
The homing operation is completed. This
Completed
option is only effective when
parameter 37-00 Application Mode is set to
[2] Position Control.
[171] Target Position
The target position is reached. This option
Reached
is only effective when
parameter 37-00 Application Mode is set to
[2] Position Control.
[172] Position
A fault occurred in the positioning
Control Fault
process. Refer to parameter 37-18 Pos. Ctrl
MG06C702